Fatek ethernet configuration tool
Fatek ethernet configuration tool















This includes starting character, station no., command code, body, error check code, ending characters, etc. Any access to the Port must comply with the format of “FATEK communication protocol” to get responses from the PLC. Among them, Port 0 is a permanent interface for FATEK communications interface, which is controlled by the CPU of the PLC, using FATEK “Standard communication driver” to manage the communication transactions of the Port, i.e. There are three types of communication interfaces, RS232、RS485 or Ethernet, to choose from in both CB and CM. If it is still not enough, communication modules can be added to expand the number of communication interfaces to 5 (PORT0~PORT4). If additional communication boards (CB) have been purchased, then it can increase to 2~3 communication interfaces (depending on the model of CB). The FBs-PLC main unit has been built in the communication port0 with optional USB or RS232 interface. All expansion cables (left) of expansion units/modules are flat ribbon cables (5cm long), which were soldered directly on the PCB, and the expansion header (right) is a 14Pin Header, with this to connect the right adjacent expansion units/modules. One type uses the same case as main unit that of the 90mm, 130mm, and 175mm, while the other two have thinner 40mm and 60mm cases, which are for expansion modules. There are three types of cases for expansion units/modules. There are four different case sizes, which are 60mm, 90mm, 130mm, and 175mm. All the Main Units of FBS-PLC have the same physical structure. With interface options in RS232, RS485, USB, Ethernet, CANopen, Zigbee and GSM, the communication peripherals are available with 15 boards and modules. Fifteen DI/DO and 19 NI/NO models are available for Expansion Units/Modules. With the combination of I/O point ranges from 10 to 60, a total of 17 models are available. The Main Units of FBS are available in three types: MA (Economy Type), MC (High-Performance Type), and MN (High-Speed NC Type). The maximum I/O numbers are 256 points for Digital Input (DI) and Digital Output (DO), 64 words for Numeric Input (NI) and Numeric Output (NO).

#Fatek ethernet configuration tool series#

The FATEK FBS Series PLC is a new generation of micro PLC equipped with excellent functions comparable to medium or large PLC, with up to five communication ports.















Fatek ethernet configuration tool